Office Buildings Access Control & Video Intercom

Office entrances need to move hundreds of staff quickly while keeping visitors, contractors and deliveries visible. The right mix is usually face terminals at the main lanes, a reception workflow for guests, and controllers on back-of-house doors.

  • 4 site challenges
  • 5 recommended products
  • 6 deployment checks
Office Buildings

In short

Typical configuration: CD-Z358, SW-HA-8ZI, SW-ZCFE-21.5 for Office Buildings. The reference design has 4 access layers and 6 deployment checks; final device counts, cable lengths and power are confirmed from the door list.

Site challenges

What makes access control at this site difficult.

01

Morning peak vs. security

Card-only lanes slow down when staff search for badges. Face recognition keeps hands free and reduces queue time, but the terminal must handle backlight from glass lobbies.

02

Visitors who arrive without notice

Reception needs a way to issue a temporary QR pass or register an ID without enrolling the visitor in the access system.

03

Back-of-house doors are forgotten

Server rooms, storage and loading bays often sit outside the lobby system. They need the same audit trail and, where required, interlock.

04

Fire and lift integration

Turnstiles must release on fire alarm, and lift access should follow the same permission logic as the lobby doors.

Reference architecture

Four access control layers, from entrance to platform.

01

Main lobby lanes

Speed gates with 8-inch face terminals. Staff use faces; temporary staff receive QR passes or cards. Lane controllers report to the access platform over TCP/IP.

02

Reception and visitor flow

A self-service terminal or reception desk registers visitors, prints a badge if required and issues a time-limited QR pass. The record links the visitor to the host and the door.

03

Back-of-house doors

Network controllers with Mifare readers cover server rooms, storage and staff doors. Anti-passback and interlock are configured where the risk requires it.

04

Lift and fire integration

The access platform sends floor permissions to the lift controller, and the turnstile controller releases on fire alarm. Both interfaces are confirmed at design stage.

Design tables

Challenges, architecture and product roles.

Site challenges and design responses

Site challengeDesign response
Morning peak vs. security Card-only lanes slow down when staff search for badges. Face recognition keeps hands free and reduces queue time, but the terminal must handle backlight from glass lobbies.
Visitors who arrive without notice Reception needs a way to issue a temporary QR pass or register an ID without enrolling the visitor in the access system.
Back-of-house doors are forgotten Server rooms, storage and loading bays often sit outside the lobby system. They need the same audit trail and, where required, interlock.
Fire and lift integration Turnstiles must release on fire alarm, and lift access should follow the same permission logic as the lobby doors.

Reference architecture by layer

LayerWhat it covers
Main lobby lanes Speed gates with 8-inch face terminals. Staff use faces; temporary staff receive QR passes or cards. Lane controllers report to the access platform over TCP/IP.
Reception and visitor flow A self-service terminal or reception desk registers visitors, prints a badge if required and issues a time-limited QR pass. The record links the visitor to the host and the door.
Back-of-house doors Network controllers with Mifare readers cover server rooms, storage and staff doors. Anti-passback and interlock are configured where the risk requires it.
Lift and fire integration The access platform sends floor permissions to the lift controller, and the turnstile controller releases on fire alarm. Both interfaces are confirmed at design stage.

Recommended products and roles

ModelCategoryRole in the design
CD-Z358 Turnstiles & Barriers A three-lane speed gate in 304 stainless steel for high-traffic lobbies.
SW-HA-8ZI Face Recognition Terminals 50,000 faces, 120 ms recognition and IP66 protection for busy entrances.
SW-ZCFE-21.5 Face Recognition Terminals A floor-standing Android terminal for visitor registration, identity checks and self-service.
PRO3000 Access Control & Readers Two-door IP controller with 55,000 cardholders and 45,000 event buffer.
AskFaceBS Management Software Manage devices, people, permissions and records from a browser on the local network.
Deployment checklist

Settle these six points before ordering.

A checklist is not decoration. It is the cheapest way to reduce site changes.

  • Count peak arrivals per minute and size lanes accordingly.
  • Check glass lobby backlight and test face recognition at noon.
  • Agree the visitor workflow: pre-registration, walk-in, ID capture, badge printing.
  • Confirm fire-alarm release and fail-safe behaviour for each lane.
  • Plan IP addresses, switch ports and power for lane controllers.
  • Decide who can issue temporary permissions and how they expire.
Frequently asked questions

Frequently asked questions

How many face terminals does a lobby need?

Start with the peak arrival rate and the acceptable queue time. A single lane typically handles 30–40 people per minute; two to four lanes are common for a mid-size office tower. Confirm with a site survey.

Can visitors use the same turnstiles as staff?

Yes, if the visitor pass is issued as a QR code or temporary card that the lane terminal can read. Many projects keep one reception-assisted lane for visitors and deliveries.

What happens during a fire alarm?

The turnstile controller receives the fire signal and releases the barriers for evacuation. Confirm the interface type and the fail-safe behaviour with the fire system contractor.

Can the system cover the lift?

Yes, lift control can use the same access levels as the lobby doors. The lift controller must support the required interface; confirm the number of floors and the protocol.

Do we need a server on site?

The browser-based platform normally runs on a local server on the same network as the devices. A small office may use a single server; multi-building sites may need a more resilient design.

Still have a question? Contact

Discuss this design

Configure this design for your office buildings site.

Share the floor plan, door list, site photos and existing platform model. We will reply within one business day with a configuration and the open questions.

  • Sales & quotation: sale@accesscontrolintercomsystem.com
  • Typical reply: within one business day
  • English / Chinese technical support

Office Buildings project inquiry

Share the site type, number of doors or apartments, and the functions you need. We will reply with a recommended configuration and a quotation.

By submitting this form you agree that we may contact you about this inquiry. We do not sell your data. Privacy policy

Keep exploring

Compare another application.

Different sites have different lane logic, wiring constraints and platform interfaces — and different designs.