Skip to content
JANOVA Access · Intercom
TUYA TY75T-HTD2 two-wire video intercom door station Video Intercom
Video Intercom

Tuya 2-wire series

TUYA TY75T-HTD2 2-Wire Video Intercom Kit

Reuse two-core cable to add video entry without pulling new network cable.

A retrofit-friendly kit for apartments and villas where only two wires run from the door to the monitor. It carries video, audio, unlock and power over the existing pair, with a 7-inch touch monitor and a 2 MP AHD door camera.

2-wire retrofit7-inch touch150 m run
System type
2-wire video intercom
Indoor monitor
7-inch IPS touch, 1024 × 600
Indoor power
AC 100–240 V, 50/60 Hz, DC 15 V 1.2 A
Indoor size
237 × 117 × 30 mm

Quick answer

Model TUYA TY75T-HTD2: System type: 2-wire video intercom · Indoor monitor: 7-inch IPS touch, 1024 × 600 · Indoor power: AC 100–240 V, 50/60 Hz, DC 15 V 1.2 A. 12 specifications, 5 FAQs. Final configuration and lead time are confirmed from the door list.

  • Model datasheet and wiring diagram with the shipment
  • Project consolidation and sample testing
  • English / Chinese technical support
Overview

The TUYA TY75T-HTD2 is a two-wire video intercom kit designed for buildings where pulling new cable is expensive or impossible. The indoor monitor connects to the door station over a two-core pair (RVV2), carrying video, audio, unlock control and power. That makes it a practical upgrade for older apartment blocks and villas with existing doorbell wiring.

The 7-inch IPS touch monitor offers 1024 × 600 resolution, supports a TF card up to 64 GB, and can be powered from AC 100–240 V. The door station uses a 2 MP AHD sensor (1/2.9-inch CMOS, 2.8 mm lens) with a 120° angle and a compact 145 × 90 × 45 mm housing. The kit supports a 150 m cable run over RVV2 and one door station with indoor units.

Use it for apartment buildings, villas, small offices and gatehouses where the existing two-wire cable is in good condition. If the site has network cabling and needs app answering across multiple buildings, choose an IP kit instead. For multi-apartment keypad entry, the TY76A-HM5-1B adds a keypad door station.

Key features

Video Intercom: what it solves at the door.

Two-wire transmission over existing RVV2 cable

7-inch IPS touch monitor at 1024 × 600

2 MP AHD door camera with 120° angle

Up to 64 GB TF card for snapshots and video

150 m cable run over RVV2

Indoor monitor and card unlocking

Specifications

System type 2-wire video intercom
Indoor monitor 7-inch IPS touch, 1024 × 600
Indoor power AC 100–240 V, 50/60 Hz, DC 15 V 1.2 A
Indoor size 237 × 117 × 30 mm
Memory TF card up to 64 GB
Cable RVV2, up to 150 m
Outdoor camera AHD 2.0 MP, 1/2.9-inch CMOS, 2.8 mm
Camera angle 120°
Outdoor size 145 × 90 × 45 mm
Operating temperature -40 °C to +60 °C
Unlocking Indoor monitor, card
Maximum combination 1 door station + indoor units

Typical applications

These are the typical deployment scenarios for this model. Lane count, mounting height and interfaces are confirmed against the site plan.

Selection note

Specifications follow the product documentation; batch or configuration differences may apply. Confirm the model, interfaces and accessory list before ordering.

Selection & installation

Align the configuration and installation conditions.

Selection table — start from the existing cable

Building conditionRecommended system
Existing two-core cable 2-wire kit, RVV2, up to 150 m
Existing four-core cable 4-wire or AHD kit, up to 150 m
Network cable or new build IP system with PoE and app/platform options
Multi-building or long distance IP system with a network backbone
Single villa gate 2-wire or 4-wire villa kit with a 7–10 inch monitor

Installation table — power, cable and commissioning

ItemTypical setting
Power Indoor-powered 2-wire, local 12 V, or PoE for IP
Cable RVV2 / RVV4 / Cat5e per kit; measure the actual route, not the plan
Monitor height 1.4–1.5 m to the screen centre
Unlock Confirm relay rating, lock type and fail-safe mode
Outdoor station Canopy, drip loop, and avoid direct sun on the camera
Test Day/night image, audio, unlock and app connection
Frequently asked questions

Frequently asked questions

Can we reuse the existing doorbell cable?

If the existing cable is a two-core pair in good condition and the run is within 150 m, it can usually be reused. Check conductor gauge, insulation and joints; a damaged cable should be replaced.

What is the maximum distance between door and monitor?

The kit is specified for up to 150 m over RVV2. Longer runs or noisy environments may need a different topology; share the actual distance and cable type.

Does it record video?

The indoor monitor supports a TF card up to 64 GB for snapshots and video, depending on the configured model. Confirm the recording behaviour in the kit datasheet before ordering.

Can one outdoor station serve several apartments?

Yes, the system supports one door station with multiple indoor units, up to the kit limit. For a keypad multi-apartment entrance, use the TY76A-HM5-1B.

Is a power supply included?

The indoor monitor is powered from AC 100–240 V and supplies the door station over the two-wire cable. Confirm the plug type for your market when ordering.

Still have a question? Contact

Request a quote

Ask about the TUYA TY75T-HTD2 configuration and price.

Tell us the quantity, target country, door type and the controller or platform you use. We will reply with the configuration, accessory list and lead time.

  • Quantity and project stage
  • Target country, voltage and plug type
  • Existing controller, turnstile or platform model

Inquiry: TUYA TY75T-HTD2

Share the site type, number of doors or apartments, and the functions you need. We will reply with a recommended configuration and a quotation.

By submitting this form you agree that we may contact you about this inquiry. We do not sell your data. Privacy policy

Keep exploring

Need to compare this model inside a full system?

Open an application guide to see where it sits in a real entrance, what it pairs with and what to check before deployment.